G5NB-EL
PCB Power Relay
A slim compact Relay with 7 A
switching capacity
• 7 A (250 VAC), 5 A (30 VDC) high capacity switching with compact
size.
• Minimum 200,000 operations durability at 5 A (250 VAC) switching.
• IEC/EN 60335-1 conformed.
• Ambient operating temperature: max. 85°C
• IEC/EN 60079-15 conformed. (Only for G5NB-1A4-EL-HA Model)
RoHS Compliant
■Model Number Legend
G 5 N B -@ @ @- @- @ -@ -@ -@
—— —— — — — —
1 2
3 4
5
6
7
8
1. Number of Poles
1 : 1-pole
4. Classification
EL : High capacity and electrical durability
2. Contact Form
A : SPST-NO (1a)
5. Conformity standard
HA : IEC/EN 60335-1 conformed
3. Enclosure rating
4 : Fully sealed
6. Coil Holding Voltage
None : Not supported
PW : Supported
7. High temperature rating
None : Not supported
A85 : High temperature rating at 85°C
G
5
N
B
E
L
-
8. Packing
None : Tray Packing
SP : Tube Packing
■Application Examples
• Home appliances
• Industrial equipment
• Building automation
■Ordering Information
Classification
Contact form
Enclosure rating
Single stable relay
SPST-NO
(1a)
Fully Sealed
Flux protection
Model
Rated coil voltage
Minimum packing unit
DC5,12,24V
100pcs./Tray
50pcs./Tube
G5NB-1A4-EL-HA(-SP)
G5NB-1A4-EL-HA-PW(-SP)
G5NB-1A-EL-HA-A85
100pcs./Tray
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5NB-1A4-EL-HA DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note 2. When ordering tape packing, add "-SP" to the model number.
Be sure since "-SP" is not part of the relay model number, it is not marked on the relay case.
1
G5NB-EL
PCB Power Relay
■Ratings
●Coil
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
5 VDC
40
125
12 VDC
16.7
720
24 VDC
8.3
2880
Must operate voltage
(V)
Must release voltage
(V)
Max. voltage
(V)
75% max.
10% min.
10 to 39%*
160% (at 23°C)
Power consumption
(mW)
Approx. 200
Approx. 50*
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* These numbers are only for -PW type. Power consumption with Holding Voltage is approx.50mW. Please confirm the detail in page 4 Coil Voltage Reduction
(Holding Voltage).
●Contacts
Item
Load
Resistive load
Contact Type
Single
Contact material
Ag-alloy (Cd free)
5 A at 250 VAC, 7 A at 250 VAC
Rated load
5 A at 30 VDC
Rated carry current
-
G
5
N
B
E
L
5 A at DC, 7 A at AC
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5 A at DC, 7 A at AC
■Characteristics
Contact resistance *1
100 mΩ max.
Operate time
10 ms max.
Release time
10 ms max.
Insulation resistance *2
1,000 MΩ min.
Between coil and contacts
4,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
750 VAC, 50/60 Hz for 1 min
Insulation
distance
Between coil and contacts
Clearance: 6 mm, Creepage: 6 mm
Impulse
withstand
voltage
Between coil and contacts
10 kV (1.2 x 50 μs)
Dielectric
strength
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock
resistance
Destruction
1,000 m/s2
Malfunction
100 m/s2
Mechanical
5,000,000 operations min.
Durability
Electrical (resistive load)
• Standard, Coil holding voltage type
200,000 operations at 250 VAC, 5 A
50,000 operations at 250 VAC, 7 A
100,000 operations at 30 VDC, 5 A
• High temperature rating type (G5NB-1A-EL-HA-A85)
100,000 operations at 250 VAC, 5 A at 85°C
50,000 operations at 250 VAC, 7 A at 85°C
Failure rate (P level) (reference value) *3 DC5V 10mA
Ambient operating temperature
-40°C to 85°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 4 g
Note. The data shown above are initial value.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. This value was measured at a switching frequency of 120 operations/min.
2
G5NB-EL
PCB Power Relay
■Engineering Data
●Maximum Switching Capacity
●Durability
10
100
AC resistive
load
5
DC resistive
load
Durability (104 operations)
Switching current (A)
7
1
50
250V AC resistive load
10
5
3
0.1
1
10
30
100
250
30V DC resistive load
30
1
1,000
0
1
2
3
4
Switching voltage (V)
●Ambient Temperature vs. Maximum Coil Voltage
Test Item: G5NB-1A4-EL-HA
Number of Relays: 5 pcs.
180
6
●Shock malfunction
Y
1,000
24 VDC
7A current
Energized
De-energized
700
1,000
X
160
Test Item: G5NB-1A4-EL-HA 24 VDC
Number of Relays: 5 pcs
1,000
Z'
Test Method: Shock is applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction is measured. The
energized voltage should be 100% of
the rated voltage.
140
120
125
X'
1,000
Z
1,000
80
60
1,000
Y'
0
20 23
40
60
80 85
G
5
N
B
E
L
Rating: 100 m/s2
100
40
7
-
Maximum coil voltage (%)
200
5
Switching current (A)
100
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
Unit: m/s2
Shock direction
X
X'
Y
Z
Z'
Y'
■Dimensions
(Unit: mm)
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
7.2max.
(7.0)*
20.5max.
(20.4)*
Terminal Arrangement/
Internal Connections
(Bottom View)
(1.05)
11.5
15.3max.
(15.0)*
(1.15)
7
Four, 1.1 dia.
1
2
3
4.7
4
3.4
@0.4
0.27
11.5
0.33
7
(No coil polarity)
0.8
4.7
*Average value
3
G5NB-EL
PCB Power Relay
■Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●UL Recognized:
(File No. E41515)
CSA Certified:
(File No. LR31928)
Model
Contact form
Coil ratings
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
SPST-NO
(1a)
5 to 24V DC
●EN/IEC, VDE Certified
Contact ratings
Number of test
operations
7A 250V AC (General Purpose) 85°C
30,000
5A 250V AC (General Purpose) 85°C
50,000
5A 30V DC (Resistive) 85°C
6,000
(Certificate No. 137575)
Model
Contact form
Coil ratings
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
SPST-NO
(1a)
5, 12, 24V DC
Contact ratings
7A 250V AC (Resistive) 85°C
5A 30V DC (Resistive) 85°C
■Precautions
-
●Please refer to “PCB Relays Common Precautions” for correct use.
G
5
Correct Use
N
B ●Coil Voltage Reduction (Holding Voltage) after Relay
E
operation
L
• If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 50% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
100%
(Rated voltage)
50%
(Holding voltage)
100ms min.
Applied
coil voltage
Rated voltage
100%
Holding voltage
50%
*
4
Coil resistance*
125Ω (5 VDC)
720Ω (12 VDC)
2880Ω (24 VDC)
Power
consumption
Approx.200 mW
Approx.50 mW
The coil resistance were measured at a coil temperature of 23°C with
tolerances of ±10%.
Number of test
operations
10,000
G5NB-EL
PCB Power Relay
■Other data
Creepage distance
6.0 mm
Clearance distance
6.0 mm
Insulation Material Group
III a
Type of insulation coil-contact circuit
Reinforced
open contact circuit
Micro disconnection
Rated Insulation Voltage
250V
Pollution degree
3
Rated voltage system
250V
Overvoltage category
III
Category of protection according to IEC 61810-1
RT III
Glow wire according to IEC 60335-1
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
Tracking Index of relay base
PTI 250V min. (housing Parts)
Flammability class according to UL94
V-0
-
G
5
N
B
E
L
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2014-2019 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. K270-E1-05
0719(0914)(O)
5